DJ-10P Short Stem
Cryogenic Globe Valve
It is suitable for all kinds of low temperature medium insulated
gas cylinder, with flexible switch and sealing rely on and anti
static characteristics.
NPT 1 / 4 as required.
valve for LNG industrial cylinder conforming to Chinese standard.
It is suitable for pressurization and depressurization of cryogenic
insulated gas cylinders with the compact structure, integrated
functions of economizer and regulator. Two types of connections
are available, which are suitable for all kinds of cylinders at home
and abroad.
Set pressure: 0.2MPa ~ 3.5Mpa
Nominal Pressure:4.0MPa
Design Temperature:-196℃~ +85℃
Suitable Media:LNG、LO2、LN2、LAr、C02
DYZ-06
Cryogenic Combined Regulator
It is suitable for pressurization and depressurization of cryogenic
insulated gas cylinders with the compact structure, integrated
functions of economizer and regulator. Two types of connections
are available, which are suitable for all kinds of cylinders at home
and abroad.
Set pressure: 0.2MPa ~ 3.5Mpa
Nominal Pressure:4.0MPa
Design Temperature:-196℃~ +85℃
Suitable Media:LNG、LO2、LN2、LAr、C02
Nominal Pressure:4.0MPa
Design Temperature:-196℃~ +85℃
Suitable Media:LNG、LO2、LN2、LAr、C02
ST-10
Four-way Joint
It is suitable for connecting insulated gas cylinder with safety
valve, pressure gauge and rupture disc.
It is suitable for safe discharge of insulated gas cylinders.
The safety valve has obtained TS certification, CE certification
and ECER110 certification.
Set pressure range: 0.4 ~ 4.0Mpa
Nominal Pressure:4.0MPa
Design Temperature:-196℃~ +85℃
Suitable Media:LNG、LO2、LN2、LAr、C02
DA-08
Cryogenic Relief Valve
It is suitable for safe discharge of insulated gas cylinders.
The safety valve has obtained TS certification, CE certification
and ECER110 certification.
Set pressure range: 0.4 ~ 4.0Mpa
Nominal Pressure:4.0MPa
Design Temperature:-196℃~ +85℃
Suitable Media:LNG、LO2、LN2、LAr、C02
Nominal Pressure:4.0MPa
Design Temperature:-196℃~ +85℃
Suitable Media:LNG、LO2、LN2、LAr、C02

DYS-15L
Cryogenic Regulator
It is a kind of pressure building device. When the
cylinder pressure is lower than the set pressure,
this valve will open automatically to increase the
pressure. When the pressure in cylinder reaches
the set pressure, this valve will close automatically
to cut off the flow to ensure the operation of
pipeline and cylinder.
DJK-25
Refueling Receptacle
It is suitable for the refueling of LNG Vehicle-mounted Cylinder.
DHK-10
Venting Receptacle
It is suitable for the venting pipeline of
Vehicle-mounted cylinder.
DH-15E
Cryogenic Check Valve
It is suitable for the refueling pipeline to avoid the flow back of medium
DYJ-06
Cryogenic Economizer
When the cylinder pressure is over the set pressure, this valve will open automatically.
BZ-06
One-way Valve
It is installed before the pressure gauge to cut off the pipeline when replacing the pressure gauge.
DA-08F
Cryogenic Relief Valve
It is suitable for the vehicle-mounted cylinder for the safety relieving
DJ-10PL
Cryogenic Globe Valve with
Excess Flow Device
It is suitable for the vehicle mounted cylinder with the excess flow device.